Operating conditions of stainless steel sewage pump

12-06-2024

The operating conditions of stainless steel sewage pumps need to be strictly followed to ensure their efficient, stable operation and extended service life. The following is a detailed analysis of the operating conditions of stainless steel sewage pumps:

1. Rated voltage and frequency

Stainless steel sewage pumps are usually designed to operate at a rated voltage of 380V (or other rated voltages, such as 220V) and a power frequency of 50Hz. Under this standard power supply, the pump can maintain optimal operating efficiency and stability.

2. Medium characteristics requirements

Medium temperature: The medium temperature that stainless steel sewage pumps can handle should not usually exceed 60°C to ensure that the pump body and seals are not damaged by high temperature.

Medium density: The medium density should not be greater than 1150kg/m³ to ensure that the pump can handle the fluid smoothly during operation.

PH value range: The PH value of the medium should be between 5-9 to avoid acidic or alkaline corrosion of the pump body.

3. Installation and use environment

Altitude limit: Stainless steel sewage pumps are suitable for areas with an altitude of no more than 1,000 meters to ensure that the performance of the pump is not affected by the high altitude environment.

Diving depth: The pump needs to be fully submerged in water to work, but the diving depth must not exceed the maximum depth specified in its design (the specific depth depends on the pump type).

Conveying medium viscosity: The annual viscosity of the medium that the pump can convey should not exceed 10000CP to avoid affecting the working efficiency of the pump due to excessive viscosity.

4. Operating frequency and working pressure

Operating frequency: The operating frequency is set according to the use environment and use requirements of the sewage pump, usually including modes such as running once a day, running twice a day, or running multiple times a day. Excessive operating frequency will accelerate the wear of the equipment and affect the operating efficiency of the sewage system.

Working pressure: The working pressure of stainless steel sewage pumps is usually between 0.5-1.0MPa, and the specific pressure value depends on the pump type and actual use requirements.

5. Other precautions

Before use, make sure that the pump body is filled with water to avoid damage to the pump when idling.

Check the operating status of the pump regularly and deal with abnormal conditions in time.

Follow the operating procedures to ensure safe and stable operation of the pump.