Sewage pump outlet pressure unit conversion

15-07-2024

The conversion of the sewage pump outlet pressure unit involves multiple different pressure units, including megapascal (MPa), kilopascal (kPa), kilogram (kg), meter water column (mH2O), etc. The following is the conversion relationship of the sewage pump outlet pressure unit compiled based on publicly released information:

1. Basic conversion relationship

Megapascal (MPa) and kilopascal (kPa)

1 MPa = 1000 kPa

Kilopascal (kPa) and Pascal (Pa)

1 kPa = 1000 Pa

Megapascal (MPa) and kilogram (kg)

In the sewage pump industry, it is customary to convert one kilogram of pressure to about 0.1 MPa. However, it should be noted that this conversion is not a strictly equal relationship, but an approximate conversion based on industry practices. A more accurate conversion relationship may require consideration of factors such as the density of the medium and the acceleration of gravity.

Megapascal (MPa) and meter of water column (mH2O)

The approximate conversion relationship is: 1 MPa ≈ 100 mH2O (but please note that this conversion relationship is based on the density and gravitational acceleration of water under standard conditions, and may be different for other media or conditions).

Sewage pump

2. Other conversion relationships

In addition to the above basic conversion relationships, there are some other common conversion relationships, such as:

1 bar

1 bar = 0.1 MPa = 100 kPa = 1.0197 kg/cm2 (but this kg/cm2 conversion is more inclined to indicate pressure rather than mass)

1 mmH2O

1 mmH2O ≈ 9.80665 Pa (this conversion relationship takes into account the density of water and the acceleration of gravity)

1 mmHg

1 mmHg ≈ 133.322 Pa (this conversion relationship is more common in the medical field and some physical measurements)

3. Precautions

When converting pressure units, attention should be paid to the conversion relationship and accuracy requirements between units. Especially in situations where high-precision measurement is required, accurate conversion formulas and values should be used.

The actual value of the sewage pump outlet pressure may be affected by many factors, such as pump performance, medium properties, pipeline conditions, etc. Therefore, when measuring and converting pressure, the influence of these factors should be comprehensively considered.

The above conversion relationship is for reference only. When converting, please choose the appropriate conversion method and value according to the actual situation and needs.

Get the latest price? We'll respond as soon as possible(within 12 hours)