Installation and disassembly of sewage pump flange

06-11-2024

The installation and removal of the sewage pump flange is an important step to ensure the normal operation and maintenance of the sewage pump. The following are the detailed steps and precautions for the installation and removal of the sewage pump flange:

1. Installation steps of the sewage pump flange

Inspection preparation:

Check the quality of the flange and the connecting pipe to ensure that there is no damage or deformation.

Prepare the required tools and materials, such as bolts, wrenches, gaskets, etc.

Cleaning before installation:

Clean the flange connection surface and pipe interface, remove oil, impurities, etc., and ensure that the connection surface is clean and flat.

Place the gasket:

Place a suitable gasket on the flange connection surface to ensure that the gasket is not damaged and in the correct position.

Align the flange:

Align the flange of the sewage pump with the pipe flange to ensure that the flange holes are consistent.

Bolt connection:

Use bolts to connect the flange tightly. Pay attention to the tightening order of the bolts. Usually, diagonal tightening is used to avoid deformation or leakage caused by uneven force on the flange.

Check the sealing:

After the installation is completed, perform a sealing check to ensure that there is no leakage at the flange connection.

2. Disassembly steps of sewage pump flange

Cut off the power supply:

Before disassembly, be sure to cut off the power supply of the sewage pump to ensure safety.

Close the valve:

Close the pipe valve connected to the sewage pump, drain the liquid in the pump, and reduce the weight and pressure of the pump.

Remove the bolts:

Use tools such as wrenches to remove the bolts on the flange in sequence, and be careful to avoid damaging the bolts or flanges.

Separate the flange:

After all the bolts are removed, gently separate the flange, and be careful to avoid damaging the gasket or flange connection surface.

Cleaning and inspection:

After disassembly, clean the flange connection surface and pipe interface, check the wear of the flange and connecting parts, and replace or repair them if necessary.

Sewage pump flange installation and disassembly steps

3. Precautions

Safety first:

When installing and disassembling the flange, be sure to follow the safety operating procedures and wear personal protective equipment.

Correct order:

The tightening and disassembly sequence of the bolts should be correct to avoid deformation or leakage caused by uneven force on the flange.

Check the sealing:

After installation, be sure to check the sealing to ensure that there is no leakage at the flange connection.

Maintenance:

Regularly inspect and maintain the flange and connecting parts to ensure they are in good condition.

By mastering the above steps and precautions, you can ensure that the installation and removal process of the sewage pump flange is safe, efficient and reliable.